Tel:0755-28137292|E-mail:sales003@turefull.cn

SiteMap|Chinese

Shenzhen Zhongfu optoelectronics Technology Co., Ltd.

PRODUCT

You are here: HomePRODUCTLED non-isolated driver

LED street LightingLED High bay lightingLED Horticulture LightingLED non-isolated driver
  • 20W LED Flood Light Power Supply

20W LED Flood Light Power Supply

Categories:LED non-isolated driver

Introduce:♦ International universal AC input range (up to 300VAC) ♦ With active PFC function ♦ Protection type: short circuit protection, over current protection, over voltage protection, over temperature protection ♦ IP66 protection level, indoor and outdoor installation ♦ Suitable for LED lighting ♦ in line with world lighting safety standards ♦ Can be applied in dry, humid, rainy environments ♦ 3...

Hotline:15915375757
  • Description

Features:

♦ International universal AC input range (up to 300VAC)
♦ With active PFC function
♦ Protection type: short circuit protection, over current protection, over voltage protection, over temperature protection
♦ IP66 protection level, indoor and outdoor installation
♦ Suitable for LED lighting
♦ in line with world lighting safety standards
♦ Can be applied in dry, humid, rainy environments
♦ 3 year warranty (please refer to warranty description)

Specification

Modeld ZF-HLD-20-36 ZF-HLD-20-43 ZF-HLD-20-54 ZF-HLD-20-65 ZF-HLD-20-72 ZF-HLD-20-88 Non-standard custom models
Output No-load voltage(MAX) 49VDC 49VDC 75VDC 75VDC 95VDC 95VDC Customized
Output current(Typ) 0.6A 0.5A 0.42A 0.33A 0.3A 0.25A Customized
Output Power(MAX) 22W 22W 23W 22W 22W 22W Customized
Ripple and noise Remarks2 4000mV 3000mV 4000mV 4000mV 4000mV 4000mV MAX 4000mV
Output voltage range 25-43VDC 25-43VDC 30-54VDC 35-65VDC 40-72VDC 50-88VDC Customized
 Conversion efficiency(Typ) ≥88% ≥89% ≥90% ≥91% ≥91% ≥92% ≥88%
Current error(MAX) ±3% ±3% ±3% ±3% ±3% ±3% ±3%
Linear adjustment rate ±3% ±3% ±3% ±3% ±3% ±3% ±3%
Load Regulation ±3% ±3% ±3% ±3% ±3% ±3% ±3%
Start Time Remarks3 ≤1000ms,≤2000ms(Full load)230VAC/115AC
Hold time(Typ) 10msFull load 230VAC/115VAC
Input Voltage range 100-300VAC Or 130-430VDC
Frequency Range 47-63HZ
Power factor(Typ) PF≥0.95  230VACFull load
Total harmonic distortion(Typ) <15%(Loaded lamps as standard)
Alternating current(Typ) <0.3A/115VAC, <0.15A/230VAC, <0.1A/277VAC
Inrush current(Typ) Cold start<50A /230VAC
Leakage current <0.75MA/300VAC
Protection Overcurrent 100%
Short circuit Protection mode: snoring, the short circuit can be restored after removal
Overload protection Maximum operating voltage limit。
Environment Operating temperature -40---+60℃
Working humidity 20-95%RH,No condensation
Storage temperature, humidity -40-+80℃,20-95%RH
Maximum temperature rise +30℃  Windless open environment, maximum temperature point of the enclosure
Vibration resistant 10-500HZ,5G 12Minute/cycle,X, Y, Z axis 72 minutes each
Safety and electromagnetic compatibility            Safety regulations Remarks4 EN 61347-1:2008+A1:2011+A2:2013 ,   EN 61347-2-13:2006 ,  EN 62493:2010
Withstand voltage I/P-O/P:3.75KVAC   I/P-FG:2KVAC   O/P-FG:1KVAC
Insulation resistance I/P-O/P, I/P-FG, O/P-FG:  100M Ohms/500VDC/25℃/70%RH
Electromagnetic compatibility emission Remarks5 Meets the EN55015,EN55022(CISPR22),Class B,EN61000-3-2 :2006+AA:2009
Electromagnetic compatibility immunity EN55024-A ,   EN61000-3-3:2013
Lightning surge Common mode L/N-FG,±3KV
Differential mode L-N,±0.8KV
Wire Rubber line Input line3*0.75²
Electronic line Output line0.75²
Shell Semi-aluminum housing Silicone filling and filling
Other MTBF ≥150Khrs  MIL-HDBK-217F(25℃)
Body size L102*W44*H28mm
Product Weight
Package carton size L188*W75*H43
Remarks 1.Unless otherwise stated, all specifications are measured at an input temperature of 230VAC. 25°C ambient temperature.
2.Ripple and noise measurement method: use a 0.52mm twisted pair cable, and the terminal should be connected with 0.1uf and 47uf capacitors in parallel and measure at 20MHz bandwidth.
3.Safety and EMC design EN60598-1, CNS15233, GB700.1, FCC part18. 4. Start-up time is measured under the cold start, frequent switch machine may make the start time change.
5.The power supply is considered to be a component used in conjunction with the terminal equipment. Because the EMC is affected by the complete unit, the terminal equipment manufacturer needs to confirm the EMC of the entire unit.

Structure size

Body size:L95*W42*H28mm

Circuit structure box

Phone:15915375757
Tel:0755-28137292
Fax:0755-28137292
Email:sales003@turefull.cn
Address:4th Floor, Building E , Jin'ao Industrial Zone, Longhua new district, Shenzhen
Copyright © 2018 Shenzhen Zhongfu optoelectronics Technology Co., Ltd.

15915375757

sales003@turefull.cn
2850606612