You are here: Home • PRODUCT • LED Horticulture Lighting • GLB series
Categories:GLB series
Introduce: 1.Model No.:ZF-GLB-150-60 2.Efficiency>91% PFC>0.98 3.Dimming option:0-10V/PWM/ resistance /1-10V short circuit, over voltage, over temperature 4.AUX Power:12V/0.2A 5.Dimmer can be built into power supply housing 6.Can be connected to the power control system 7.Protection function: short circuit, over voltage, over temperature
Features
1.Universal input voltage 100-277V,up to 305V
7.Protection function: short circuit, over voltage, over temperature
Parameter:
Model No.
ZF-GLB-150-60
Output
NO-load voltage(MAX)
61VDC
Output current(Typ)
2.7A
Output power(MAX)
162W
Ripple or Noise Re.2
800mV
Output voltage range
38-60VDC
Efficiency(Typ)
≥90%
Current error(MAX)
±2%
Line regulation
±2%
Load regulation
±2%
Setup,rise time
≤1500ms,≤100ms(full load)115VAC/230VAC
Hold up time(Typ)
10ms full load 230VAC/115VAC
Dimming
Dimming control Mode Remark.
Series/parallel/ PWM signal control
Maximum dimming range in series/parallel
0-100%,Minimum boot brightness/6%
Power Maintenance Voltage Note 5
25VDC
Input
Input voltage range
100-285VAC or 130-400VDC
frequency range
47-63HZ
PFC(Typ)
PF≥0.98 230VAC Full load
THD(Typ)
<15%(Standard for load lamp)
AC current(Typ)
<1.4A/115VAC, <0.9A/230VAC, <0.5A/277VAC
Surge current(Typ)
Cold start<80A /230VAC
Leakage current
<0.75MA/300VAC
Protection
Over-current
100%
Short-circuit
Protection mode: hiccup, short circuit can be recovered after removal
Over-load
Maximum operating voltage limit.
Environment
Working Temperature
-40---+60℃
Working Humidity
20-95%RH,No condensation
Storage temperature, humidity
-40-+80℃,20-95%RH
MAX. temperature rise
+40℃ Airless open environment, shell MAX. temperature point
Vibration
10-500HZ,5G 12 Min./1cycle, period for 72min. each along X, Y, Z axes
Safety and standards
Safety Code Note 4
EN 61347-1:2008+A1:2011+A2:2013 , EN 61347-2-13:2006 , EN 62493:2010
Isolation resistance
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1KVAC I/P-DIM:3.75KVAC O/P-DIM:1.5KVAC
Withstand voltage
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25℃/70%RH
EMC emission
EN55015,EN55022(CISPR22),Class B,EN61000-3-2 :2006+AA:2009
EMC immunity
EN55024-A , EN61000-3-3:2013
Lightning Surge
L/N-FG
L/N-FG,±6KV
L-N
L-N,±4KV
Rubber cable
Input 3*0.75²
Rubber cable
Output 2*0.75²
Series/parallel Control Line
4/6 core 0.42 telephone line, RJ45 must be used 6P6 Core Crystal Head
case
Full Aluminum case
Silica filling
Others
MTBF
≥150Khrs MIL-HDBK-217F(25℃)
Main body size
L188*W68*H39mm
Net weight
Packing size with Box
L188*W75*H43
Remaks
1. if not specified, all specifications are measured at ambient temperature VAC.25℃230.
2. ripple and noise measurement method: a 0.52mm twisted pair wire is used, and the terminal should parallel the capacitance of 0.1uf and 47uf bandwidth measurement.
3. the start-up time is measured under the start-up of the cold machine, frequent switching machines may change the start-up time.
4. the slow dimming of the lamp after dimming is turned off is a normal phenomenon, because the output filter electrolytic capacitance capacity is large, and the discharge capacity of dimming to the minimum power is weaker than that of the maximum power. Therefore, the power in electrolytic capacitance can be maintained for a long time, making the dimming time relatively slow.
5. the power supply through dimming control off the no-load voltage, that is, the final load voltage of the lamp is lower than the holding voltage, the lamp will have a weak brightness
6.TUVEN61347-1,EN61347-2-13,IEC/EN60968-1.2004A1:2006 6. Safety Design
7. power supply is regarded as a combination of components and terminal equipment. Because the EMC is affected by the whole device, the terminal equipment manufacturer needs to confirm the whole device EMC.
Structure dimensions