Tel:0755-28137292|E-mail:sales003@turefull.cn

SiteMap|Chinese

Shenzhen Zhongfu optoelectronics Technology Co., Ltd.

PRODUCT

You are here: HomePRODUCTLED High bay lighting

LED street LightingLED High bay lightingLED Horticulture LightingLED non-isolated driver
  • 60W LED high bay light power supply

60W LED high bay light power supply

Categories:LED High bay lighting

Introduce: Features: ♦ Constant current output mode ♦ Built in active PFC function ♦ IP67/IP65 rating for indoor and outdoor rating ♦ 3-5 years warranty Applications ♦ LED high bay lighting ♦ LED stage lighting ♦ LED street lighting Dimensions Φ110.5*H57.5mm Specification Modeld ZF-HBG-60-36 ZF-HBG-60-43 ZF-HBG-60-54 ...

Hotline:15915375757
  • Description

Features:

♦ Constant current output mode
♦ Built in active PFC function
♦ IP67/IP65 rating for indoor and outdoor rating
♦ 3-5 years warranty

Applications

♦ LED high bay lighting
♦ LED stage lighting
♦ LED street lighting

Dimensions

Φ110.5*H57.5mm

Specification

Modeld ZF-HBG-60-36 ZF-HBG-60-43 ZF-HBG-60-54 ZF-HBG-60-65 ZF-HBG-60-72 ZF-HBG-60-88 Non-standard custom models
Output No-load voltage(MAX) 45VDC 55VDC 75VDC 75VDC 95VDC 95VDC Customized
Output current(Typ) 1.8A 1.5A 1.1A 1A 0.9A 0.7A Customized
Output Power(MAX) 65W 65W 65W 65W 65W 65W Customized
Ripple and noise Remarks2 3000mV 3000mV 3000mV 3000mV 3000mV 3000mV MAX 3000mV
Output voltage range 25-43VDC 25-43VDC 30-54VDC 35-65VDC 40-72VDC 50-88VDC Customized
 Conversion efficiency(Typ) ≥90% ≥90% ≥91% ≥91% ≥92% ≥92% ≥90%
Current error(MAX) ±3% ±3% ±3% ±3% ±3% ±3% ±3%
Linear adjustment rate ±3% ±3% ±3% ±3% ±3% ±3% ±3%
Load Regulation ±3% ±3% ±3% ±3% ±3% ±3% ±3%
Start Time Remarks3 ≤1000ms,≤2000ms(Full load)230VAC/115AC
Hold time(Typ) 10msFull load 230VAC/115VAC
Input Voltage range 100-300VAC Or 130-430VDC
Frequency Range 47-63HZ
Power factor(Typ) PF≥0.98  230VACFull load
Total harmonic distortion(Typ) <10%(Loaded lamps as standard)
Alternating current(Typ) <0.8A/115VAC, <0.45A/230VAC, <0.35A/277VAC
Inrush current(Typ) Cold start<50A /230VAC
Leakage current <0.75MA/300VAC
Protection Overcurrent 100%
Short circuit Protection mode: snoring, the short circuit can be restored after removal
Overload protection Maximum operating voltage limit。
Environment Operating temperature -40---+60℃
Working humidity 20-95%RH,No condensation
Storage temperature, humidity -40-+80℃,20-95%RH
Maximum temperature rise +30℃  Windless open environment, maximum temperature point of the enclosure
Vibration resistant 10-500HZ,5G 12Minute/cycle,X, Y, Z axis 72 minutes each
Safety and electromagnetic compatibility Safety regulations Remarks4 EN 61347-1:2008+A1:2011+A2:2013 ,   EN 61347-2-13:2006 ,  EN 62493:2010
Withstand voltage I/P-O/P:3.75KVAC   I/P-FG:2KVAC   O/P-FG:1KVAC
Insulation resistance I/P-O/P, I/P-FG, O/P-FG:  100M Ohms/500VDC/25℃/70%RH
Electromagnetic compatibility emission EN55015 , EN55022(CISPR22),Class B,EN61000-3-2 :2006+AA:2009
Electromagnetic compatibility immunity EN55024-A , EN61000-3-3:2013
Lightning surge Common mode L/N-FG,±4KV
Differential mode L-N,±2KV
Wire Rubber line Input line3*0.75²
Rubber line Output line2*0.75²
Shell Semi-aluminum housing Silicone filling and filling
Other MTBF ≥150Khrs  MIL-HDBK-217F(25℃)
Body size Φ110.5*H51mm
Product Weight  
Package carton size  
Remarks 1.Unless otherwise stated, all specifications are measured at an input temperature of 230VAC. 25°C ambient temperature.
2.Ripple and noise measurement method: use a 0.52mm twisted pair cable, and the terminal should be connected with 0.1uf and 47uf capacitors in parallel and measure at 20MHz bandwidth.
3.The startup time is measured under the cold start, and frequent switching machines may change the startup time.
4.Safety designTUVEN61347-1,EN61347-2-13,IEC/EN60968-1.2004+A1:2006
5.The power supply is considered to be a component used in conjunction with the terminal equipment. Because the EMC is affected by the complete unit, the terminal equipment manufacturer needs to confirm the EMC of the entire unit.

Block Diagram

Declaration

1.the picture is for reference only, products in kind prevail.
2.Due to errors in the test equipment, the conversion efficiency is only for reference.
3.power can not be soaked in water for a long time.

Product Usage Notes

1. When the device is powered, please pay attention to the correct installation of the input and output terminals.
2. When the power supply is turned on for the first time, if a light flash occurs, check the DC output terminal; if it is confirmed that the load voltage of the DC output terminal is lower than the minimum operating voltage, when the load voltage is lower than the minimum operating voltage, the power supply is not in operation. In the normal work area, various abnormal conditions will occur.
3. When the power is turned on for the first time, if the load power is low, check the DC output voltage and confirm whether the DC output voltage is lower than the maximum operating voltage. If the load voltage is higher than or equal to the maximum operating voltage, When the power supply enters the constant voltage operation mode, the power supply loses the constant current function and changes to the load impedance constant current. After encountering this situation, it is necessary to replace the power supply with higher operating voltage to properly match the lamps.

Warranty instructions

1.the warranty date start date is the product date of manufacture
2.The product damage caused by using the environment beyond the nominal range of the specification is not covered by the warranty.
3.Product damage caused by incorrect installation and use is not covered by the warranty.
4. Product failure caused by long-term immersion in water is not covered by the warranty.
5.Users will not warranty after disassembling the product.

Phone:15915375757
Tel:0755-28137292
Fax:0755-28137292
Email:sales003@turefull.cn
Address:4th Floor, Building E , Jin'ao Industrial Zone, Longhua new district, Shenzhen
Copyright © 2018 Shenzhen Zhongfu optoelectronics Technology Co., Ltd.

15915375757

sales003@turefull.cn
2850606612