Tel:0755-28137292|E-mail:sales003@turefull.cn

SiteMap|Chinese

Shenzhen Zhongfu optoelectronics Technology Co., Ltd.

PRODUCT

You are here: HomePRODUCTLED street Lighting

LED street LightingLED High bay lightingLED Horticulture LightingLED non-isolated driver
  • 50W LED street light power supply

50W LED street light power supply

Categories:LED street Lighting

Introduce: Features: ■Universal input voltage design(90Vac~305Vac) ■Output voltage and current parameters support the client settings ■High power factor, low harmonics ■High efficiency design (up to 90%) ■Protection Design: Short-circuit, over-voltage, over-temperature ■suitable for LED Lighting ■IP65/IP67 grade,could be install in indoor and outdoor ■3years warranty Dimming optiona 3 in...

Hotline:15915375757
  • Description

Features:

■Universal input voltage design(90Vac~305Vac)
■Output voltage and current parameters support the client settings
■High power factor, low harmonics
■High efficiency design (up to 90%)
■Protection Design: Short-circuit, over-voltage, over-temperature
■suitable for LED Lighting
■IP65/IP67 grade,could be install in indoor and outdoor
■3years warranty

Dimming optiona

3 in1 online dimming(Equipped with 3-in-1 dimming function, through the product dimming cable access resistance / PWM signal / (0 ~ 10Vdc) level of any signal,Programming (output current control settings, up to 2 dimming section)

Structure

L*W*H:L130*W45*H33mm

Specification

Modeld ZF-HLD-50-12 ZF-HLD-50-24 ZF-HLD-50-36 ZF-HLD-50-42 ZF-HLD-50-48 ZF-HLD-50-54 Customize
Output No-load voltage(MAX) 12VDC 24VDC 37VDC 43VDC 49VDC 55VDC /
Output current(Typ) 4.16A 2.08A 1.38A 1.15A 1.05A  0.925A customize
Output Power(MAX) 50W 50W 52W 52W 52W 52W customize
Ripple and noise Remarks2 300mV 300mV 300mV 300mV 300mV 300mV 300mV
Output voltage range 12VDC 24VDC 25-36VDC 25-42VDC 25-48VDC 38-54VDC customize
 Conversion efficiency(Typ) ≥83% ≥85% ≥86% ≥86% ≥87% ≥88% ≥90%
Current error(MAX) ≤105% ≤105% ±2% ±2% ±2% ±2% ±2%
Linear adjustment rate / / ±2% ±2% ±2% ±2% ±2%
Load Regulation / / ±2% ±2% ±2% ±2% ±2%
Start Time Remarks3 ≤800ms,≤1500ms(Full load)230VAC/115AC
Hold time(Typ) 10msFull load 230VAC/115VAC
Input Voltage range 100-300VAC Or 130-430VDC(When the AC input voltage is higher than 277VAC, the APFC is turned off and the power supply works without PFC correction.)
Frequency Range 47-63HZ
Power factor(Typ) PF≥0.98  230VACFull load
Total harmonic distortion(Typ) <15%(Loaded lamps as standard)
Alternating current(Typ) <0.65A/115VAC, <0.35A/230VAC, <0.25A/277VAC
Inrush current(Typ) Cold start<80A /230VAC
Leakage current <0.75MA/300VAC
Protection Overcurrent 100%
Short circuit Protection mode: snoring, the short circuit can be restored after removal
Overload protection Maximum operating voltage limit。
Over temperature protection Product internal temperature monitoring point>Start after 90 °C, reduce the output current as the temperature rises (the dimming product does not have this function)
Environment Operating temperature -40---+60℃
Working humidity 20-95%RH,No condensation
Storage temperature, humidity -40-+80℃,20-95%RH
Maximum temperature rise +30℃  Windless open environment, maximum temperature point of the enclosure
Vibration resistant 10-500HZ,5G 12Minute/cycle,X, Y, Z axis 72 minutes each
Safety and electromagnetic compatibility Safety regulations Remarks4 EN 61347-1:2008+A1:2011+A2:2013 ,   EN 61347-2-13:2006 ,  EN 62493:2010
Withstand voltage I/P-O/P:3.75KVAC   I/P-FG:2KVAC   O/P-FG:1KVAC
Insulation resistance I/P-O/P, I/P-FG, O/P-FG:  100M Ohms/500VDC/25℃/70%RH
Electromagnetic compatibility emission EN55015 , EN55022(CISPR22),Class B,EN61000-3-2 :2006+AA:2009
Electromagnetic compatibility immunity EN55024-A , EN61000-3-3:2013
Lightning surge Common mode L/N-FG,±6KV
Differential mode L-N,±5KV
Wire Rubber line Input line3*0.75²
Rubber line Output line2*0.75²
Shell All aluminum Shell Silicone filling and filling
Other MTBF ≥150Khrs  MIL-HDBK-217F(25℃)
Body size L130*W44*H32mm
Product Weight
安装尺寸 L150*W44*H32
Note 1.All parameters not specially mentioned are measured at 230vAc input,rated current and 25℃of ambient temperature
2. ripple and noise measurement method using a 0.5 - mm twisted pair, and terminal capacitor in parallel with 0.1uF and 47uF, were measured in a 20MHZ bandwidth. 3. safety design of EN60598-1 and EMC, CNS15233, GB700.1, FCC, part18.
4. start time is measured in the cold start, switch frequently may make the starting time of change.
5. the power supply is considered as a component, which is used in conjunction with the terminal equipment. Because the EMC is affected by the whole set of equipment, the terminal equipment manufacturer needs to make a EMC confirmation of the whole set of devices
6. reference Warranty Statement

Block diagram

Dimming function (optional)

※ The output current can be adjusted by potentiometer with DIM+, DIM-connected 1~10Vdc, 10V PWM signal, and maximum resistance of 100K.

※ When using the potentiometer to control the dimming, only one product can be controlled. If you need to control multiple products, you need to change the maximum value of the potentiometer. The resistance change calculation formula is: 100K/parallel control product = demand resistance The use of potentiometer to control multiple products is also affected by other conditions, and the actual experience is poor, so it is not recommended to use potentiometer to control multiple products.)

※ When controlling 10 products with 1~10Vdc, 10V PWM signal, ensure that the controller output current is ≥3mA

※ After the product is powered on, the DIM+ output line cannot be short-circuited with the LED+ output line to prevent the high voltage of the LED+ output from damaging the constant current control system inside the product.

※ Adjust the reference resistance of the output current (typical)

Resistance Value 10KΩ 20KΩ 30KΩ 40KΩ 50KΩ 60KΩ 70KΩ 80KΩ 90KΩ 100KΩ OPEN
Rated current percentage 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%-108%

※1-10V Dimming Function Adjusts Output Current (Typical)

Voltage adjustment 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN
Rated current percentage 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%-108%

※10V PWM Signal Adjust Output Current Value (Typical) Frequency Range: 100Hz-3KHz

Duty Ration 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN
Rated current percentage 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%-108%

Dimming connection block diagram of lighting device using controller to turn on/off

2. Dimming method 2: timing dimming

Timer dimming internally uses a micro-controller as a timer. A dimming ratio of 5% to 100% can be achieved.
This dimming method uses the power-on time as 0 o'clock. When the power supply starts the timer, it will restart at 0:00:00:00. Once the power is turned off or the power-on time is lost, the time will start again.
The minimum current changes by 1%. The maximum current changes by 95%. The minimum time set value is 1 second, and the maximum time setting value is infinite. For example, the output power of the customer is reduced to 70% after 3 hours of start-up, 50% after 5 hours, 35% after 6.5 hours, and then maintained. This can be achieved by this function.
Note: The start time of the dimming and the percentage of the dimming output current are set by the customer and cannot be changed once shipped.
This control mode cannot turn off the power.
There are two ways of current regulation, one is real-time, and the other is gradual, such as reducing the weight to 100% and reducing it to 50%. In real time, it only takes 1 second to reduce the current by 100% to 50%. The gradual change is a gradual decrease at a rate of 1% per second. The reduction from 100% to 50% takes 50 seconds to complete. . Customers can choose a suitable change in a more practical environment.

Declaration

 1.the picture is for reference only, products in kind prevail.
 2.Due to errors in the test equipment, the conversion efficiency is only for reference.
 3.power can not be soaked in water for a long time.

Product Usage Notes

1. When the device is powered, please pay attention to the correct installation of the input and output terminals.
2. When the power supply is turned on for the first time, if a light flash occurs, check the DC output terminal; if it is confirmed that the load voltage of the DC output terminal is lower than the minimum operating voltage, when the load voltage is lower than the minimum operating voltage, the power supply is not in operation. In the normal work area, various abnormal conditions will occur.
3. When the power is turned on for the first time, if the load power is low, check the DC output voltage and confirm whether the DC output voltage is lower than the maximum operating voltage. If the load voltage is higher than or equal to the maximum operating voltage, When the power supply enters the constant voltage operation mode, the power supply loses the constant current function and changes to the load impedance constant current. After encountering this situation, it is necessary to replace the power supply with higher operating voltage to properly match the lamps.

Warranty instructions

1.the warranty date start date is the product date of manufacture.
2.The product damage caused by using the environment beyond the nominal range of the specification is not covered by the warranty.
3.Product damage caused by incorrect installation and use is not covered by the warranty.
4. Product failure caused by long-term immersion in water is not covered by the warranty.
5.Users will not warranty after disassembling the product.

Phone:15915375757
Tel:0755-28137292
Fax:0755-28137292
Email:sales003@turefull.cn
Address:4th Floor, Building E , Jin'ao Industrial Zone, Longhua new district, Shenzhen
Copyright © 2018 Shenzhen Zhongfu optoelectronics Technology Co., Ltd.

15915375757

sales003@turefull.cn
2850606612